Vibration appears only at running speed. Is that the arm or a fault?
Validated 13 November 2026
Applies to
- Line
- Steadicam
- Attribute
- Any arm
Resolution
- 01
Reproduce the vibration while standing still. Boom the arm fully up and fully down and watch both arm sections. This is the test Tiffen publishes for arm behavior.
- 02
Watch whether the upper arm follows the forearm smoothly. A section that lags, leads or hangs up at the extremes of travel is a ride or lift setting fault and not a broken arm.
- 03
Adjust the ride if a section hangs up. Too much iso-elasticity makes the segments lock at the top or bottom of boom travel; too little makes the arm track poorly through the middle. Turn the Ride knob counterclockwise until the segment begins to lock at the extremes, then back clockwise a couple of turns.
- 04
Re-check the ride against the load. Every G-Series arm becomes progressively less iso-elastic as its lift is increased, so a heavier build needs the Ride knob turned to increase iso-elasticity.
- 05
Re-set the lift so each section floats about 5 to 10 degrees above horizontal at mid boom, then re-check the ride. Lift and ride interact.
- 06
Check that nothing on the sled is loose: monitor, batteries, camera, accessories, rods and clamps. A loose component on the sled is a published vibration source on a Volt rig, and the mechanical case is the same.
- 07
If a Volt is fitted, check the control box is rigidly mounted to the stage, the motor drive is tight on the gimbal yoke, the tilt and roll pulley screws are tight, the gimbal handle is tight, and the belts are tight. Then reduce the tilt and roll strength settings and test again.
- 08
Use the right hand on the gimbal handle to damp vertical movement while running. Tiffen assigns that hand the job of eliminating the bounce of the springs.
- 09
Contact Tiffen Steadicam service with the arm model and the payload weight if the arm still vibrates after the ride and lift are set and the sled is tight.
Cause
A Steadicam arm is a spring system carrying a mass, so it has a natural frequency. Walking and running drive it at different rates, and only one of them may sit near that frequency, which is why the vibration can appear at running speed and not at walking speed.
The ride setting changes how closely the arm's lifting power tracks the load through its travel, which is what Tiffen calls iso-elasticity. Set wrong for the load, the arm locks at the extremes of travel or fails to track in the middle, and both of those show up as a jolt at each step. A loose component anywhere on the sled adds a second mass on its own spring, which does the same.